What are Vibro (aggregate) Piers

Vibro (aggregate) Piers is a ground improvement technique that is used to increase soil strength and reduce its compressibility.  This technique is very similar to the Vibro Replacement technique but installed in a different way.  It is mainly used to reinforce fine grained soils to build a composite soil-pier mass that has increased strength and stiffness.  Aggregate Piers has a higher modulus than in situ soils, therefore, attracts the structural loads and reduces the structure settlement.

Benefits

Reduce and control total and differential foundation settlement
Increase soil bearing capacity, leading to smaller foundation sizes.
Increase soil stiffness and strength
Reduce liquefaction risk
Improve slope stability
Reduce permeability

Applications

Recommended for sites with variable layer of sands, silts, and clay.
Effective for seismic mitigation under structures or embankments.
Suitable for low to mid-rise new construction buildings.
Applicable for area loads, including tanks and embankments.
Can be used to address sinkhole triggering and collapse.
Highly cost-effective when compared to deep foundation systems.
helical piles

It's Time To Build...What to Expect

Geotek Design-Build will develop and provided a signed and sealed design detailing Vibro (Aggregate) Piers plan.
Site clearing and access preparation will precede the Vibro (Aggregate) Piers process. Typically prepared by site contractor.
#57 Stone is used to backfill.
Substantial quantities of rock backfill are necessary, necessitating site access for deliveries by rock trucks
Vibro (Aggregate) Piers is generally performed under a performance specification, with specified minimum improvement criteria.
Modulus load testing can be performed to verify bearing capacity and settlement requirements.
After our work is completed and testing is done, Geotek Design-Build provide a certification package to allow final site grading and foundation construction to begin.

Process

Vibro (Aggregate) Piers offer a cost-effective and efficient ground improvement solution, serving as a viable alternative to deep foundation systems in appropriate conditions. This technique involves installing compacted aggregate columns into the soil to enhance load-bearing capacity and control settlement. Key benefits include increased bearing capacity, effective settlement control, reduced construction time, cost savings, and minimal environmental impact. Vibro (Aggregate) Piers are versatile and suitable for various soil types, particularly silts and loose sands, making them an excellent choice for ensuring structural stability and optimizing construction efficiency.

Step 1 Step 2 Step 3

Aggregate Piers are typically installed in fine-grained soils that are cohesive. First, a hole is pre-drilled in the ground with a diameter that is equal or smaller than the final pier design parameter. There are two ways of installing and compacting the pier that depend on the water table elevation and the risk of the pre-drilled hole collapsing.

If the hole stays open, the hole is filled with stone from the top in lift and compacted using a Vibro Probe that is lowered into the hole.

If the water table is high and there is a risk of the hole collapsing, a Bottom Feed system consisting of Vibro Probe and a stone feed tube. The stone is fed from the bottom of the tube in lifts and compacted using the vibratory action of the probe.

Design and Quality Control

The purpose of Vibro (aggregate) Piers is the reinforcement of the existing soft soil.  Aggregate Piers have a higher modulus than existing soils; therefore, attract more load and reduce total and differential settlement.

In addition to settlement reduction, the composite soil-piers mass has an increased strength and stiffness which increases allowable soil bearing capacity. The soil being treated, the degree of reinforcement required, the type of vibrator being used, and production rates all have an influence on the spacing of the Vibro (aggregate) Piers probes.

The construction process of Aggregate Piers Columns affects to a certain extent their performance.  The following aspects are of particular importance and should be carefully evaluated during construction:

  • The As-Built diameter of the stone column
  • The influence of the stone column installation of the surrounding ground and on previously installed columns.

Recording the backfill quantity in each column is crucial for accurately determining the actual pier diameter. Upon completion, the total column volume is calculated by correlating the total backfill used with any adjustments for surface wastage. To ensure the maximum practical compacted column diameter is achieved, the vibrator’s ammeter should be continuously monitored, and the probe should be repeatedly lifted and dropped after each layer of stone is added.

The design assumptions and performance of the Aggregate Pier ground improvement system is evaluated using full scale modulus load test.

Visual Portfolio, Posts & Image Gallery for WordPress
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare