What are Rigid Inclusions?
Rigid Inclusions are a ground improvement technique that uses stiff elements that have much higher modulus than in-situ soils, arranged in a grid pattern and extending to a suitable bearing stratum to transfer overburden stresses through weak soil layers. The elements are typically made of grout/concrete, but steel and timber can be used as well. To ensure uniform stress distribution to all RI elements, a bridging layer (load transfer platform, or LTP) comprised of compacted granular soil reinforced with layers of geogrids is constructed directly atop the RI grid. Arching within this layer distributes essentially most of overburden stresses to the RI elements.
Rigid Inclusions serves as soil reinforcement as well creating a reinforced soil mass that has an increased stiffness and reduced compressibility. Rigid Inclusions are typically used when soils are very soft to confine stone columns (bulging problems and presence of peat and organics) or when vibration is a concern.
Benefits
Applications
It's Time To Build...What to Expect
Process
Where applicable, Rigid Inclusions provides a cost-effective alternative to Deep Foundation systems and is less time consuming. It allows the use of conventional shallow foundations instead of costly pile caps and eliminates the need to structurally connect the foundation elements to the elements in the ground.
Rigid Inclusions can be installed using different methods that depend on soil type, application, and proximity to existing structures:
- Vibrated method using a mandrel vibrated to the design depth. This method causes vibration and is not suitable near existing structures. This method does not generate any soil spoils
- Augured method that is similar to Auger Cast Piles that doesn’t produce vibration. This method generates soil spoils.
- Displacement method using a displacement tool that does not produce vibration nor general spoils.
Regardless of installation method, the tool is inserted in the ground to the design depth. At this depth, a pump is used to supply the grout to the tip of the tool and then the tool is withdrawn at a controlled rate to ensure a uniform rigid inclusion cross section.
The grout fills the hole created by the installation tool and is brought all the way to the work platform and then dug to the design elevation.
After completion of all Rigid Inclusions, a load transfer platform is constructed between the top of the elements and the bottom of the footings. The footings are then constructed as regular shallow foundations without the need of structural connection between the elements and the foundation.
Design and Quality Control
Rigid Inclusions (RIs) are designed to transfer most of the load from the supported structure to a bearing stratum using a Load Transfer Platform (LTP). RIs are more efficient than traditional piles because they allow load sharing between the elements and the soils. This load sharing allows the use of smaller diameter and shorter embedment than traditional piles. The LTP plays an integral role in the transmission of the load from the structure to the Rigid Inclusions elements. The LTP can be reinforced with single or multiple layers of geogrid or geotextile depending on loads, application, and soil conditions.
The Rigid Inclusions are typically unreinforced elements and not structurally connected to the footings. RI elements are designed for structural and geotechnical capacities to ensure proper performance of the system.
Geotek Construction team has over a decade of experience in the design of Rigid Inclusion projects across the southeast region. With tens of designs completed and installed, Geotek Constructions can provide you with the most cost effective-solution.
The construction process of Rigid Inclusions and the Load Transfer Platform affects their performance. The following aspects are of particular importance and should be carefully evaluated during construction
- Penetration depth
- Soil resistance monitoring
- Grout volume
- Grout strength.
Typically, a data acquisition system (DAQ) is used to continuously monitor the different parameters and typically supplemented with hand logs. The DAQ logs show the different parameters for every column installed. Grout samples shall be collected and tested for compressive strength. Typically, grout strength is measured at 3, 7, and 28 days.
After the installation of the Rigid Inclusion elements and prior to placing concrete, the soil shall be prepared and compacted for the Load Transfer Platform installation. The LTP shall be constructed in lifts following the geotechnical engineering of record requirements.
Geotek Construction In-house quality production manager software enables us to capture and analyze data in real time and validate the performance of the ground improvement being carried out. The performance of the Rigid Inclusion ground improvement system is quantified using full scale load tests on a single element or a group of elements.
Frequently Asked Questions
Eastport Hotel
Mariner Street Apartments Vibro Replacement
Mariner Street Apartments Helical Piles
Sarasota Commerce Center
Sarasota Bayside Apartments
MCSO Fleet Maintenance Facility
SMH Education Parking Garage
Orange Station Garage
Spacebox Apollo Beach
Canopy @ West River II
Tampa Bay Oaks Phase 2
Tysons Apartments
UF Whitney Marine Research
The Centerpointe Apartments
La Cruz Bonita
North Florida Mega Industrial Park WWTP
Evelyn City Lofts
Harbor Island Bridge Force Main
Novel Beach Park Apartments