What is Ductile Iron Piles
Ductile Iron Piles (DIP) are a deep foundation system that transmit the structural loads to a deeper bearing stratum bypassing soft and compressible soils. DIP are a small-diameter, low-vibration driven pile system often used as a high-value alternative to Micropiles, Helical Piles and other traditional piling systems. The system uses modular, pre-fabricated, high-strength ductile iron pipes ranging in diameter from 98 mm (3.9 in) to 170 mm (6.7 in) to develop working capacities ranging between 25 and 100 tons depending on soil conditions. DIPs are installed using an excavator-mounted hydraulic hammer fitted with a special drive adapter to drive the pile into the ground using a combination of excavator crowd force and the percussive hammer energy. The excavator mounted setup allows these piles to be installed in tight access areas.
Benefits
Applications
It's Time To Build...What to Expect
Process
DIPs are prefabricated in typical lengths of 5 meters (16.4 ft) per pile and employ a plug & drive connection system that allows for rapid pile connections in the field and accommodates variable pile lengths without additional equipment or splicing. Although driven, the high frequency hydraulic hammer results in high frequency, low vibration levels (typically less than 1 ips). The DIPs are capped with a bracket that transfers the loads from the foundation.
There are 2 methods to install DIP based on their design. A method for end bearing DIP, and a method for friction DIP.
For end bearing DIP, a flat or pointed shoe is used at the end of the hollow pile and the lead section is driven into the ground using a high frequency impact energy hydraulic hammer. The following DIP spigot end is inserted in the socket of the installed pile until the pile reaches a predetermined depth or refusal. After completion of the pile, and if required, grout and a cap is added to the pile.
For friction DIP, an oversized conical end cap used at the end of the hollow pile and the lead section is driven into the ground using a high frequency impact energy hydraulic hammer. The end cap is designed to have a larger diameter than the pile to facilitate grouting the exterior of the pile. The following DIP spigot end is inserted in the socket of the installed pile until the pile reaches a predetermined depth or refusal. After completion of the pile, and if required, grout and a cap is added to the pile.
Design and Quality Control
The design of DIP includes geotechnical and structural design of a single or a group of elements. The design of structural connection between the DIP and the pile cap is typically handled by the structural engineer.
DIP develop their geotechnical capacity by end bearing or friction. The structural capacity of the element is carried out to ensure that applied stresses do not exceed the allowable stress of the steel. The DIP can be designed to carry tension, compression, and lateral loads.
During installation of all the DIP, the driving rate and alignment is monitored. The performance and load-settlement behavior of the HP is typically measured using a full-scale load test.
Eastport Hotel
Mariner Street Apartments Vibro Replacement
Mariner Street Apartments Helical Piles
Sarasota Commerce Center
Sarasota Bayside Apartments
MCSO Fleet Maintenance Facility
SMH Education Parking Garage
Orange Station Garage
Spacebox Apollo Beach
Canopy @ West River II
Tampa Bay Oaks Phase 2
Tysons Apartments
UF Whitney Marine Research
The Centerpointe Apartments
La Cruz Bonita
North Florida Mega Industrial Park WWTP
Evelyn City Lofts
Harbor Island Bridge Force Main
Novel Beach Park Apartments